Field dynamic balancer: daily maintenance precautions for field dynamic balancer
Published:
2021-11-17 11:12
The principle of the on- site dynamic balancer is advanced, and the process design is exquisite. The instrument makes full use of microprocessor and digital signal processing technology, and all chips are soldered on the circuit board. The chassis is metal structure, fully enclosed, dust-proof effect, dust-proof and anti-jamming treatment. A built-in DC power link increases the suitability of the instrument and application in hazardous locations. As long as the user does not violate the operating regulations, the instrument will perform well in the application.
The process of dynamic balance testing and counterweighting must pay attention to safety. In addition to the safety of instruments and equipment, personnel safety is particularly important. Users must take care of themselves, take care of property, and prevent accidents.
1. When the on-site dynamic balancer is not used , it should be put back into the packing box and put it in before cleaning the sensor and cables.
2. The on-site dynamic balancer should be stored in a dry environment. In a high-humidity environment, a desiccant should be added to the storage box for dehumidification, and necessary ventilation and moisture-proof treatment should be performed before use.
3. Before each use, please clean the light-emitting and light-receiving parts of the photoelectric head with a clean cotton thread or toilet paper to prevent dust accumulation and reduce the possibility of generating rotational pulses.
4. All cable connectors have been treated to prevent pulling, and the cable itself cannot be bent hard repeatedly or stretched excessively, which will cause the internal leads to break. When placing cables, prevent heavy objects from being crushed and people from kicking or tripping.
5. The place where there is a possibility of failure is the connection between the cable and the sensor or the host. This field balancer uses good household connectors and is locked with nuts. Sometimes the measurement cannot be stabilized due to poor contact. If necessary, use a small screwdriver to push the four-lobed copper core in the socket to increase contact.
6. When the on-site dynamic balancer uses the built-in battery, if the power supply is insufficient (< 6.5V ), the backlight on the front panel will not light up, reminding the user to charge as soon as possible.
7. Do not leave the electromagnetic chuck open for a long time. It is recommended to put them back in the box after sucking in pairs. It must also be protected from the effects of a drop or drop, making it lose its magnetism.
Guangzhou Zhuoxuanjin Machinery Equipment Co., Ltd. focuses on the innovative concept of dynamic balancing technology and is a dynamic balancing machine manufacturer. Mainly engaged in dynamic balancing machines, balancing machines, motor dynamic balancing machines, air-conditioning dynamic balancing machines, rotor dynamic balancing machines, fan dynamic balancing machines, impeller dynamic balancing machines, on- site dynamic balancing instruments and other products. Advocating the concept of learning design and production, emphasizing innovation, quality, technology, and service, integrating dynamic balance research and development, design, production, and after-sales one-stop service, focusing on providing dynamics for various high-speed rotating workpieces (from 500 to 10,000 rpm or more) Balance detection, correction and dynamic balance cleaning equipment; continue to contribute to the balance machine business with perfect service and technology.
Related news
2021-09-15
New products of Zhuo Xuanjin will be released, and Shenzhen Exhibition will debut for the first time
Shenzhen International Small Electrical Machinery and Motor Industry, Magnetic Material Exhibition is jointly created by many authoritative organizations around the world. It is held in Shenzhen, China every year. It has been successfully held for 15 times so far. It is one of the two major motor magnetic material industry events in China, and also an important procurement platform for small electrical machinery and magnetic materials in the world.
2021-09-15
On May 19, 2018, the 16th Shenzhen International Small Electrical Machinery, Motor Industry and Magnetic Materials Exhibition was successfully concluded in Shenzhen Convention and Exhibition Center.
2021-09-15
Iranian customers visit dynamic balancer equipment
On November 19, Iranian customers came to our company to visit the small fan blade dynamic balancing machine. The efficient dynamic balancing measurement speed, high-precision dynamic balancing requirements and simple dynamic balancing machine operation were important reasons for attracting Iranian customers to visit this time。
2021-09-15
On November 27, our technical engineers went to the customer's factory to successfully complete the installation, commissioning and training of the YYQ-5 traditional universal dynamic balancer.
2021-09-15
Double drive automatic positioning balancing machine for new energy motor
In recent years, more and more attention has been paid to environmental problems, but the deterioration of the environment has not been improved. The environment we rely on for survival depends on our joint efforts. In order to better protect the earth, more and more motor manufacturers are beginning to realize the need to protect the environment and assume this responsibility. New energy vehicles and electric vehicles have gradually entered our vision and started to be used.
2021-09-15
On November 27, our technical engineers went to the customer's factory to successfully complete the installation, commissioning and training of the YYQ-5 traditional universal dynamic balancer.